-... +Rule: 1    
-the original rules in some structured format +if     the day is Monday ​ 
-...+or     the day is Tuesday 
 +or     the day is Wednesday  
 +or     the day is Thursday 
 +or     the day is Friday  
 +then   today is a workday 
 + 
 +Rule: 2    
 +if    the day is Saturday  
 +or    the day is Sunday  
 +then  today is the weekend 
 + 
 +Rule: 3    
 +if    today is workday  
 +and   the time is '​between 9 am and 5 pm'  
 +then  operation is '​during business hours'​ 
 + 
 +Rule: 4    
 +if    today is workday  
 +and   the time is '​before 9 am'  
 +then  operation is 'not during business hours'​ 
 + 
 +Rule: 5    
 +if    today is workday  
 +and   the time is 'after 5 pm'  
 +then  operation is 'not during business hours'​ 
 + 
 +Rule: 6    
 +if    today is weekend  
 +then  operation is 'not during business hours'​ 
 + 
 +Rule: 7    
 +if    the month is January  
 +or    the month is February 
 +or    the month is December  
 +then  the season is summer  
 + 
 +Rule: 8    
 +if    the month is March  
 +or    the month is April 
 +or    the month is May  
 +then  the season is autumn  
 + 
 +Rule: 9   
 +if    the month is June  
 +or    the month is July 
 +or    the month is August  
 +then  the season is winter  
 + 
 +Rule: 10    
 +if    the month is September  
 +or    the month is October 
 +or    the month is November  
 +then  the season is spring  
 + 
 +Rule: 11    
 +if    the season is spring  
 +and   ​operation is '​during business hours'  
 +then  thermostat_setting is '20 degrees'​ 
 + 
 +Rule: 12    
 +if    the season is spring  
 +and   ​operation is 'not during business hours'  
 +then  thermostat_setting is '15 degrees'​ 
 + 
 +Rule: 13    
 +if    the season is summer  
 +and   ​operation is '​during business hours'  
 +then  thermostat_setting is '24 degrees'​ 
 + 
 +Rule: 14    
 +if    the season is summer  
 +and   ​operation is 'not during business hours'  
 +then  thermostat_setting is '27 degrees'​ 
 + 
 +Rule: 15    
 +if    the season is autumn  
 +and   ​operation is '​during business hours'  
 +then  thermostat_setting is '20 degrees'​ 
 + 
 +Rule: 16    
 +if    the season is autumn  
 +and   ​operation is 'not during business hours'  
 +then  thermostat_setting is '16 degrees'​ 
 + 
 +Rule: 17    
 +if    the season is winter  
 +and   ​operation is '​during business hours'  
 +then  thermostat_setting is '18 degrees'​ 
 + 
 +Rule: 18 
 +if    the season is winter  
 +and   ​operation is 'not during business hours'  
 +then  thermostat_setting is '14 degrees'​
 </​code>​ </​code>​
  